No lines found for the selected filter.
Tinned Electrical Cable for Port Applications - 0,6kV - 90°C
Port / Crane Cables
| Nominal Section (mm²) |
Construction |
Insulation/Jacket Thickness (mm) |
Outer Diameter (mm) |
KG/KM |
| 2,5 |
37 x 2,5mm |
3,5 |
33,20 |
1.645 |
View specifications
Tinned Electrical Cable for Aerospace Use - 0,6kV - 120/150°C
Aerospace Cables
| Wire Gauge (AWG) |
Equivalence (mm²) |
Insulation Thickness (mm²) |
Outer Diameter (mm) |
Current (A) |
Weight (kg/km) |
Electrical Resistance (ohm/km) |
| 22 |
0,3247 |
0,25 |
1,27 |
12 |
5,00 |
59,40 |
| 20 |
0,5191 |
0,25 |
1,47 |
17 |
7,00 |
36,70 |
| 18 |
0,8235 |
0,25 |
1,64 |
23 |
8,00 |
23,20 |
| 16 |
1,307 |
0,25 |
1,96 |
31 |
13,00 |
14,60 |
| 14 |
2,082 |
0,25 |
2,35 |
42 |
20,00 |
8,960 |
| 12 |
3,307 |
0,30 |
2,80 |
55 |
31,00 |
5,640 |
| 10 |
5,260 |
0,35 |
3,70 |
75 |
51,00 |
3,540 |
| 8 |
8,367 |
0,40 |
4,50 |
115 |
79,00 |
2,230 |
| 6 |
13,299 |
0,45 |
6,30 |
154 |
167,00 |
1,400 |
| 4 |
21,147 |
0,45 |
7,80 |
205 |
248,00 |
0,882 |
| 2 |
33,630 |
0,60 |
9,80 |
280 |
374,00 |
0,554 |
View specifications
Tinned Electrical Cable Single-Core - Railway - 0,6/1kV - 120/155°C
Railway Cables
| Wire Gauge (mm²) |
Insulation Thickness (mm) |
Outer Diameter (mm) |
Current 120°C (A) |
Current 155°C (A) |
Weight (kg/km) |
Electrical Resistance (ohm/km) |
| 0,5 |
0,6 |
2,2 |
14 |
17 |
9,0 |
40,10 |
| 0,75 |
0,6 |
2,4 |
19 |
22 |
12,0 |
26,70 |
| 1,0 |
0,6 |
2,5 |
22 |
27 |
15,0 |
20,00 |
| 1,5 |
0,6 |
2,8 |
28 |
35 |
20,0 |
13,70 |
| 2,5 |
0,8 |
3,6 |
41 |
50 |
33,0 |
8,21 |
| 4,0 |
0,9 |
4,4 |
55 |
70 |
49,0 |
5,09 |
| 6,0 |
0,9 |
5,1 |
72 |
89 |
70,0 |
3,39 |
| 10 |
1,0 |
6,3 |
100 |
123 |
112,0 |
1,95 |
| 16 |
1,2 |
7,8 |
136 |
173 |
174,0 |
1,24 |
| 25 |
1,2 |
9,1 |
181 |
231 |
248,0 |
0,795 |
| 35 |
1,2 |
10,5 |
228 |
290 |
356,0 |
0,565 |
| 50 |
1,4 |
12,3 |
285 |
366 |
498,0 |
0,393 |
| 70 |
1,5 |
14,4 |
357 |
457 |
691,0 |
0,277 |
| 95 |
1,6 |
16,2 |
437 |
558 |
907,0 |
0,210 |
| 120 |
1,7 |
18,4 |
508 |
676 |
1194,0 |
0,164 |
View specifications
Tinned Electrical Cable Single-Core - Naval XLPE - 0,6-1kV - 90°C
Marine Cables
| Wire Gauge (mm²) |
Insulation Thickness (mm) |
Outer Diameter (mm) |
Current (A) |
Weight (kg/km) |
Electrical Resistance (ohm/km) |
| 0,5 |
0,7 |
4,50 |
11 |
25,0 |
40,10 |
| 0,75 |
0,7 |
4,75 |
14 |
30,0 |
26,70 |
| 1,0 |
0,7 |
4,85 |
17 |
32,0 |
20,00 |
| 1,5 |
0,7 |
5,10 |
24 |
38,0 |
13,70 |
| 2,5 |
0,7 |
6,05 |
34 |
54,0 |
8,21 |
| 4,0 |
0,7 |
6,10 |
46 |
65,0 |
5,09 |
| 6,0 |
0,7 |
6,80 |
61 |
87,0 |
3,39 |
| 10 |
0,7 |
7,80 |
80 |
130,0 |
1,95 |
| 16 |
0,7 |
8,85 |
118 |
185,0 |
1,24 |
| 25 |
0,9 |
10,45 |
152 |
268,0 |
0,795 |
| 35 |
0,9 |
12,00 |
185 |
376,0 |
0,565 |
| 50 |
1,0 |
13,70 |
230 |
575,0 |
0,393 |
| 70 |
1,0 |
15,61 |
300 |
717,0 |
0,277 |
| 95 |
1,1 |
17,58 |
370 |
918,0 |
0,210 |
| 120 |
1,2 |
19,85 |
420 |
1197,0 |
0,164 |
View specifications
Tinned Electrical Cable PP - Naval - Naval XLPE - 0,6-1kV - 90°C
Marine Cables
| Wire Gauge (mm²) |
No. of Cores x Section |
Insulation Outer Diameter (mm) |
Sheath/Jacket Outer Diameter (mm) |
Current (A) |
Weight (kg/km) |
Electrical Resistance (ohm/km) |
| 1,0 |
2 x 1,0 |
2,65 |
7,70 |
14 |
70,0 |
20,00 |
| 1,5 |
2 x 1,5 |
2,90 |
8,25 |
21 |
84,0 |
13,70 |
| 2,5 |
2 x 2,5 |
3,30 |
9,05 |
28 |
108,0 |
8,21 |
| 4,0 |
2 x 4,0 |
3,90 |
10,25 |
38 |
147,0 |
5,09 |
| 6,0 |
2 x 6,0 |
4,60 |
11,85 |
49 |
204,0 |
3,39 |
| 10,0 |
2 x 10,0 |
5,60 |
14,0 |
69 |
307,0 |
1,95 |
| 16,0 |
2 x 16,0 |
6,70 |
16,0 |
97 |
624,0 |
1,24 |
| 25,0 |
2 x 25,0 |
8,25 |
19,70 |
130 |
648,0 |
0,795 |
| 1,0 |
3 x 1,0 |
2,65 |
8,10 |
13 |
84,0 |
20,0 |
| 1,5 |
3 x 1,5 |
2,90 |
8,90 |
18 |
106,0 |
13,7 |
| 2,5 |
3 x 2,5 |
3,30 |
9,55 |
24 |
134,0 |
8,21 |
| 4,0 |
3 x 4,0 |
3,90 |
10,85 |
34 |
187,0 |
5,09 |
| 6,0 |
3 x 6,0 |
4,60 |
12,55 |
43 |
263,0 |
3,39 |
| 10,0 |
3 x 10,0 |
5,60 |
14,65 |
60 |
402,0 |
1,95 |
| 16,0 |
3 x 16,0 |
6,70 |
17,4 |
84 |
586,0 |
1,24 |
| 25,0 |
3 x 25,0 |
8,25 |
20,90 |
113 |
992,0 |
0,795 |
| 35,0 |
3 x 35,0 |
9,60 |
24,0 |
140 |
1203,0 |
0,565 |
| 1,5 |
4 x 1,5 |
2,90 |
9,45 |
16 |
124 |
13,7 |
| 2,5 |
4 x 2,5 |
3,30 |
10,40 |
22 |
167 |
8,21 |
| 4,0 |
4 x 4,0 |
3,90 |
12,05 |
30 |
240 |
5,09 |
| 6,0 |
4 x 6,0 |
4,60 |
13,95 |
39 |
331 |
3,39 |
| 10,0 |
4 x 10,0 |
5,60 |
16,30 |
55 |
513 |
1,95 |
| 16,0 |
4 x 16,0 |
6,70 |
19,15 |
76 |
750 |
1,24 |
| 25,0 |
4 x 25,0 * |
8,25 |
23,45 |
102 |
1135 |
0,795 |
| 50,0 |
4 x 50,0 * |
11,30 |
32,04 |
161 |
2290 |
0,393 |
| 2,5 |
5 x 2,5 |
3,30 |
11,20 |
19 |
207 |
8,21 |
View specifications
Tinned Electrical Cable Single-Core - Railway - 1,8/3kV - 120/155°C
Railway Cables
| Wire Gauge (mm²) |
Insulation Thickness (mm) |
Outer Diameter (mm) |
Current 120°C (A) |
Current 155°C (A) |
Weight (kg/km) |
Electrical Resistance (ohm/km) |
| 1,5 |
1,8 |
5,2 |
28 |
35 |
43,0 |
13,70 |
| 2,5 |
1,8 |
5,6 |
41 |
50 |
56,0 |
8,21 |
| 4,0 |
1,8 |
6,2 |
55 |
70 |
72,0 |
5,09 |
| 6,0 |
1,8 |
6,9 |
72 |
89 |
96,0 |
3,39 |
| 10 |
1,8 |
7,9 |
100 |
123 |
139,0 |
1,95 |
| 16 |
1,8 |
9,0 |
136 |
173 |
198,0 |
1,24 |
| 25 |
1,8 |
10,3 |
181 |
231 |
276,0 |
0,795 |
| 35 |
2,0 |
12,10 |
228 |
290 |
399,0 |
0,565 |
| 50 |
2,0 |
13,50 |
285 |
366 |
535,0 |
0,393 |
| 70 |
2,0 |
15,4 |
357 |
457 |
720,0 |
0,277 |
| 95 |
2,0 |
17,0 |
437 |
558 |
928,0 |
0,210 |
| 120 |
2,0 |
19,0 |
508 |
676 |
1214,0 |
0,164 |
View specifications
Tinned Electrical Cable Single-Core - UL-1230 - 0,6kV - 105°C
UL 1230/1232 Cables
| Wire Gauge (AWG) |
Equivalence (mm²) |
Insulation Thickness (mm²) |
Outer Diameter (mm) |
Current (A) |
Weight (kg/km) |
Electrical Resistance (ohm/km) |
| 20 |
0,5191 |
0,76 |
2,45 |
13 |
11,00 |
36,70 |
| 18 |
0,8235 |
0,76 |
2,70 |
18 |
14,00 |
23,20 |
| 16 |
1,307 |
0,76 |
2,98 |
26 |
19,00 |
14,60 |
| 14 |
2,082 |
0,76 |
3,36 |
37 |
27,00 |
8,960 |
| 12 |
3,307 |
0,76 |
3,83 |
49 |
39,00 |
5,640 |
| 10 |
5,260 |
0,76 |
4,61 |
67 |
59,00 |
3,540 |
View specifications
Tinned Electrical Cable Single-Core - UL-1232 - 0,6kV - 105°C
UL 1230/1232 Cables
| Wire Gauge (AWG) |
Equivalence (mm²) |
Insulation Thickness (mm²) |
Outer Diameter (mm) |
Current (A) |
Weight (kg/km) |
Electrical Resistance (ohm/km) |
| 8 |
8,367 |
1,14 |
6,20 |
86 |
100,0 |
2,230 |
| 6 |
13,299 |
1,52 |
8,02 |
104 |
165,00 |
1,400 |
| 4 |
21,147 |
1,52 |
9,37 |
167 |
247,00 |
0,882 |
| 2 |
33,630 |
1,52 |
10,82 |
201 |
355,00 |
0,554 |
| 1 |
42,409 |
2,03 |
12,88 |
240 |
474,00 |
0,435 |
| 1/0 |
53,475 |
2,03 |
13,72 |
287 |
565,00 |
0,348 |
| 2/0 |
67,433 |
2,03 |
15,07 |
321 |
714,00 |
0,276 |
| 3/0 |
85,028 |
2,03 |
16,51 |
406 |
892,00 |
0,219 |
| 4/0 |
107,220 |
2,03 |
18,16 |
450 |
1112,00 |
0,172 |
View specifications
Tinned Electrical Cable PP - Boat Cable - 0,6kV - 105°C
UL 1426 Boat Cables
| Wire Gauge (AWG) |
Insulation Thickness (mm²) |
Insulation Outer Diameter (mm) |
Sheath/Jacket Thickness (mm²) |
Sheath/Jacket Outer Diameter (mm) |
Current (A) |
Weight (kg/km) |
Electrical Resistance (ohm/km) |
| 2x18 |
0,76 |
2,70 |
1,00 |
7,40 |
14 |
63,00 |
23,20 |
| 2x16 |
0,76 |
2,98 |
1,00 |
7,97 |
21 |
76,00 |
14,60 |
| 2x14 |
0,76 |
3,36 |
1,00 |
8,72 |
30 |
97,00 |
8,960 |
| 2x12 |
0,76 |
3,83 |
1,00 |
9,67 |
39 |
128,00 |
5,640 |
| 2x10 |
0,76 |
4,61 |
2,00 |
13,22 |
54 |
234,00 |
3,540 |
| 2x8 |
0,76 |
5,43 |
2,00 |
14,86 |
69 |
312,00 |
2,230 |
| 2x6 |
0,76 |
6,50 |
2,00 |
17,01 |
83 |
456,00 |
1,400 |
| 2x4 |
1,10 |
8,53 |
2,00 |
21,07 |
134 |
709,00 |
0,882 |
| 3x18 |
0,76 |
2,70 |
1,00 |
7,81 |
13 |
74,00 |
23,20 |
| 3x16 |
0,76 |
2,98 |
1,00 |
8,41 |
18 |
92,00 |
14,60 |
| 3x14 |
0,76 |
3,36 |
1,00 |
9,22 |
26 |
120,00 |
8,960 |
| 3x12 |
0,76 |
3,83 |
1,00 |
10,25 |
34 |
160,00 |
5,640 |
| 3x10 |
0,76 |
4,61 |
2,00 |
13,91 |
47 |
288,00 |
3,540 |
| 3x8 |
0,76 |
5,43 |
2,00 |
15,68 |
60 |
392,00 |
2,230 |
| 3x6 |
0,76 |
6,50 |
2,00 |
17,99 |
73 |
596,00 |
1,400 |
| 3x4 |
1,10 |
8,53 |
2,00 |
22,35 |
117 |
937,00 |
0,882 |
| 4x18 |
0,76 |
2,70 |
1,00 |
8,51 |
12 |
96,00 |
23,20 |
| 4x16 |
0,76 |
2,98 |
1,00 |
9,19 |
17 |
120,00 |
14,60 |
| 4x14 |
0,76 |
3,36 |
1,00 |
10,09 |
24 |
156,00 |
8,960 |
| 4x12 |
0,76 |
3,83 |
1,00 |
11,24 |
32 |
210,00 |
5,640 |
| 4x10 |
0,76 |
4,61 |
2,00 |
15,11 |
44 |
369,00 |
3,540 |
| 4x8 |
0,76 |
5,43 |
2,00 |
17,09 |
56 |
510,00 |
2,230 |
| 4x6 |
0,76 |
6,50 |
2,00 |
19,68 |
68 |
757,00 |
1,400 |
| 4x4 |
1,10 |
8,53 |
2,00 |
24,58 |
109 |
1.199,00 |
0,882 |
View specifications
Tinned Electrical Cable Single-Core - Boat Cable - 0,6kV - 105°C
UL 1426 Boat Cables
| Wire Gauge (AWG) |
Equivalence (mm²) |
Insulation Thickness (mm²) |
Outer Diameter (mm) |
Current (A) |
Weight (kg/km) |
Electrical Resistance (ohm/km) |
| 18 |
0,8235 |
0,76 |
2,70 |
18 |
14,00 |
23,20 |
| 16 |
1,307 |
0,76 |
2,98 |
26 |
19,00 |
14,60 |
| 14 |
2,082 |
0,76 |
3,36 |
37 |
27,00 |
8,960 |
| 12 |
3,307 |
0,76 |
3,83 |
49 |
39,00 |
5,640 |
| 10 |
5,260 |
0,76 |
4,61 |
67 |
59,00 |
3,540 |
| 8 |
8,367 |
1,14 |
6,20 |
86 |
100,0 |
2,230 |
| 6 |
13,299 |
1,52 |
8,02 |
104 |
165,00 |
1,400 |
| 4 |
21,147 |
1,52 |
9,37 |
167 |
247,00 |
0,882 |
| 2 |
33,630 |
1,52 |
10,82 |
201 |
355,00 |
0,554 |
| 1 |
42,409 |
2,03 |
12,88 |
240 |
474,00 |
0,435 |
| 1/0 |
53,475 |
2,03 |
13,72 |
287 |
565,00 |
0,348 |
| 2/0 |
67,433 |
2,03 |
15,07 |
321 |
714,00 |
0,276 |
| 3/0 |
85,028 |
2,03 |
16,51 |
406 |
892,00 |
0,219 |
| 4/0 |
107,220 |
2,03 |
18,16 |
450 |
1112,00 |
0,172 |
View specifications